ODV-1D Thermal Printers

 

Overview

Our exclusive Online Data Validation (ODV™) with barcode validation ensures 100% accurate barcodes 100% of the time.

Eliminate compliance fees and returned shipments due to unreadable barcodes . Easy to use, ODV reads each barcode as it is printed, strikes out rejected barcodes and reprints a new label. Available as an option on the T8000 and T6000 thermal printers. For more information visit the individual printer pages.

 

Specification

BARCODES SUPPORTED

• Code 39
• CODABAR
• Interleafed 2 of 5
• Code 93
• Code 128
• UPC/EAN plus add-ons
• PDF417 (Limited)
• Check linear start and stop bar only

 

LABEL REQUIREMENTS

• Quiet Zone: Minimum 10 times x-dimension
• Barcodes per line: UP to 4 codes on the same horizontal line
• Barcodes per form: Up to 99 codes per form
• Barcode orientation: Picket fence only
• Horizontal Spacing: Minimum of .5” between codes on the same horizontal line
• Barcode Height: Minimum barcode height is .13”
• TOF to TOF Minimum distance .5”

 

LINEAR BARCODE SPECIFICATIONS

• STANDARD ODV-OPTION
•  Scan Width: 4” (200mm). X-Dimension (min.): 6.6 mil(0.17mm) Min. Code Height: 0.13” (3.3mm)
•  Scan Width: 6.5” (165mm), X-Dimension (min.): 10 mil (0.25mm) Min. Code Height: 0.14” (3.6mm)
•  Scan Width: 8.5” (216mm), X-Dimension (min.): 13mm(0.33mm) Min. Code Height: 0.20” (5.1mm)
• WIDE ODV OPTION
•  Scan Width: 8.5” (216mm), X-Dimension (min.): 13 mil (0.33mm) Min. Code Height: 0.20” (5.1mm)
•  *Scan width centered around middle part of print width.**Wide ODV available as a field option only.

 

PRINT RUN REPORT

• Number of forms printed
• Number of bad forms
• Bar width deviation of last barcode
• Number of codes printed
• Average bar with deviation

 

VALIDATION ERRORS ACTIONS

• Retry Form (default), Stop and Retry, Grade and Report, Rescan Form, Rescan and Retry, Rescan and Stop, Overstrike, Stop
 

VALIDATION ERROR NOTIFICATION MODES

• Printer Display
• Printer Audible Alarm
• Printer Status Light
• Remote Notification

 

TELEMENTARY REPORTS

• Telemetry Path: Network Port
• Data Contents (Selectable)
• Short Pass/Fail quality results
• Validation: Pass/Fail quality results + actual decoded data
• Full: Validation + all measure parameters

 

AGENCY CERTIFICATIONS

• cTUVus
• CE
• Class 2 Laser Product
• EN60950-1:2006 + A11:2009
• EN60825-1:2007

Contact Us For More Information